290-500KV HV POWER CABLE

Application:

290/500kV HV cables fall into the category of EHV XLPE insulated power cables. As a core product for 500kV EHV power transmission networks, they replace overhead lines of the same voltage class for underground/tunnel laying in urban power grids, industrial parks and cross-regional transmission projects. Featuring large transmission capacity, excellent insulation, strong anti-environmental interference and small floor space, they are widely used in overhead-to-underground transformation of main power grids, cross-sea/river transmission and power grid construction in urban core areas.

Construction:

1.Conductor: Circular Stranded Compacted Conductor(≤800mm2),Milliken Conductor(>800mm2)

2.Conductor Screen:Super Smooth Semi-Conductive Compound

3.Insulation: Super Clean Cross Linked Polyethylene(XLPE)

4.Insulation Screen:Super Smooth Semi-Conductive Compound

5.Binder Tape:Semi-Conductive Tape

6.Metal Sheath: Corrugated Aluminum Sheath/Lead Sheath/Aluminum Laminated Tape

7.Anti-Corrosive Layer:Cable Asphalt

8.Outer Sheath: Polyvinyl Chloride(PVC) or Polyethylene(PE)

9.Conductive Layer: Graphite

10.Optional: Copper Wire Screen,Metal Wire Screen 

Technical Parameters

                            Rated Voltage:290/500KV
YJLW03:CU/XLPE/CAS/HDPE                         YJLW02:CU/XLPE/CAS/PVC
Nominal area
of conductor
 mm²800800*10001200140016001800200022002500
Thickness of
insulation
  mm34.034.033.033.032.032.031.031.031.031.0
Thickness of
aluminum tape
  mm2.92.93.03.03.03.13.23.23.23.3
Thickness of
outer sheath
  mm6.06.06.06.06.06.06.06.06.06.0
Approx.outer
   diameter
  mm148.0148.4150.8154.2155.2158.7159.6162.6166.1169.0
Approx.weight
   ( kg/km)
  Cu21520216002378625793275922995631707340603606139503
   Max.DC
resistance of
conductor  at
20℃(Ω/km)
  Cu0.02210.02210.01760.01510.01290.01130.01010.00900.00830.0072
Current ratings(A)
Soil
  Cu962100111191201128713611425148615301596
Air
  Cu1248130114861613175318781991210121882306
Soil
… ·
  Cu1050109012081285136614311490154015721624
Air
··
  Cu1246129714681587171418241923201520862183