Product Detail

Type 2S 1.1KV & 3.3KV Individually Screened

Home Products Type 2S 1.1KV & 3.3KV Individually Screened

Type 2S 1.1KV & 3.3KV Individually Screened

AS/NZS 1972:2006 AS/NZS 1125 AS/NZS 3808
High-quality materials
International standards compliant
Durable construction
Long service life
Quality tested
Custom lengths available
Overview

Type 2S 1.1KV & 3.3KV Individually Screened

Application:

The Type 2S Mining Cables are highly versatile, rubber-insulated solutions designed for dynamic applications, including the internal wiring of machines and inter-machine connections. Renowned for their superior flexibility and durability, they are also a preferred choice for specialized longwall lighting circuits. These cables are configurable with various cores, such as dedicated pilot, control, or twisted pair and screened cores, ensuring both reliable power delivery and stable signal transmission.

Construction:

Conductors: Stranded tinned annealed copper conductor.

Insulation: EPR.

Filling: Elastomer centre filler.

Pilot/Control Cores: EPR covered and composite screened flexible stranded tinned copper conductor.

Individual/Collectively Composite Screen (earth conductor): Tinned annealed copper braiding interwove with

polyester yarn.

Sheath: Heavy duty CPE sheath.

                          Type 2S Individually Screened

Type 2S Collectively Screened

Technical Parameters: 4个表格

Number
of Core
Nominal
Conductor
Area
Strand
Size
Insulation
Thickness
Core ScreenPilot ConductorNominal
Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Weight
Strand
Size
Area of
Screen
Number
of Pilots
Strand
Size
Thickness
of
Covering
 mm²No/mmmmmmmm² No/mmmm  mmmmkg/100m
 Type 2S 1.1/1kV Individually Screened
31077/0.401.20.27.93  1.822.169
41077/0.401.20.27.94  1.823.093
216126/0.401.20.29.02  1.822.081
3 16126/0.401.20.29.03  1.823.4100
4 16126/0.401.20.29.04  1.826.8135
31077/0.401.20.27.9330/0.201.0  1.822.587
216126/0.401.20.29.0230/0.201.0  1.822.788
316126/0.401.20.29.0330/0.201.0  1.827.7130
325209/0.401.40.211.3330/0.201.0  1.829.2165
335285/0.401.40.212.4330/0.201.0  1.831.6200
350380/0.401.60.2517.5330/0.201.0  1.936.1260

Type 2S 1.1/1kV Individually Screened

                    Type 2S 1.1/1kV Individually and Collectivly Screened

Number
of Core
Nominal
Conductor
Area
Strand
Size
Insulation
Thickness
Core ScreenPilot ConductorNominal
Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Weight
Strand
Size
Area of
Screen
Number
of Pilots
Strand
Size
Thickness
of
Covering
 mm²No/mmmmmmmm² No/mmmm  mmmmkg/100m
 Type 2S 1.1/1kV Individually and Collectivly Screened
301.530/0.251.00.314.0  1.932.6170

                     Type 2S 3.3/3.3KV Individually Screened

Number
of Core
Nominal
Conductor
Area
Strand
Size
Insulation
Thickness
Core ScreenPilot ConductorNominal
Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Weight
Strand
Size
Area of
Screen
Number
of Pilots
Strand
Size
Thickness
of
Covering
 mm²No/mmmmmmmm² No/mmmm  mmmmkg/100m
 Type 2S 3.3/3.3KV Individually Screened
31077/0.403.00.211.3330/0.251.0  1.828.9130
316126/0.403.00.212.4330/0.251.0  1.831.3160
325209/0.403.00.213.6330/0.251.0  1.934.8210
335285/0.403.00.215.3330/0.251.0  2.037.8250
350380/0.403.00.217.0330/0.251.0  2.141.3305
370203/0.673.00.330.5330/0.251.0  2.246.8415
395259/0.673.00.330.5330/0.251.0  2.349.6490
3120336/0.673.00.447.5330/0.251.0  2.555.0620

                  Type 2S 1.1/1kV Collectively Screened

Number of
Core
Nominal
Conductor
  Area
Strand SizeInsulation
Thickness
Core ScreenNominal
Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Weight
Strand SizeArea of
Screen
 mm²No/mmmmmmmm²mmmmkg/100m
Type 2S 1.1/1kV Collectively Screened
21.530/0.251.00.205.31.814.717
41.530/0.251.00.2012.11.819.926
61.530/0.251.00.2022.61.825.735
161.530/0.251.00.25113.11.847.171
201.530/0.251.00.25159.01.853.282
Downloads

Documents & Certifications

Product DatasheetComing soon

Ready to Discuss Your Project?

Our engineering team is ready to provide technical specifications, custom solutions, and competitive quotes.